Thanks once again. Due to current medical problems. I do not feel confident that I can strip the whole printer down, and not really got suitable area to do so. This head will have to take its chance. Put in a new Photo Black/ink. New scan attached. I print few photos these days mostly web...
Thanks for your support and comments regarding the purge unit and PB cart/ink. I have looked as best I can at the purge unit flooded it with water. It does not pool but drains away. I tried checking the gaskets pads are clean and this time fluid still drained away but more slowly. Frankly to...
Head been soaking all night a few black marks on the paper towel but nothing significant. Again the tube over the PG nozzle does not drain, yet all the others including the Photo Black flow freely through in a few seconds. This is not my method, been showed on the Forum by several contributors...
Thank you I did find the site and have downloaded the PDF file. I duly dismantled the Printer. made 1 mistake took screws out of both covers, which meant I had the whole scanner unit floating free, putting pressure on the wiring. I took the front cover (over the printhead) to access the timing...
Yes you are right Closer examination of nozzle print show misalignment. Rightly or wrongly I tried the auto head align then a nozzle check first print colours were all grey after 2 cleans colour was back but PG nozzle was back to its old missing segments. I checked timing strip was dirty...
spent all day yesterday using both fairy liquid and Window W5 cleaner and left it soaking alnight in dish of fairy liquid. Dried and topped all carts where a bit low. Result not perfect but much improved. Hopefully the missing segments may recover with use. The black bars on left do not look...
Thanks for your comments. Spent all day on this Print Head tried Fairy with 5% strength Ammonia, W5 Window Cleaner (The Hats favourite) Isopropanol Tried Push/Pull with a syringe. The paper underneath showed little colour and definitely not the shape of the PG nozzle. Rinsed off with cold...
Stratman I am trying your Fairy liquid suggestion plus some 5% Ammonia. Rinsed head first in warm water. Then immersed the print head in an aluminium tray on kitchen roll paper folded 4 times. Gently pumped head and down, most action seem to be coming from the Magenta nozzle. For a flow test I...
Thanks for resetting Navigator I have got version Ex.2.0 and unfortunately it appears a lot different to your version. However I have been able to select Un sharp mask off and Descreen On. Image adjust not there. However I have manually made the following adjustments scanning 150dpi from 300dpi...
Not a good scan but yellow/magenta/cyan are fine black I have been previously told is electrical and has been like that for a long time. The real problem is the number of segments missing from the PG scan. Normally is perfect. Have noted comments and with my limited computer knowledge will...